FUNEL
The FUNEL module includes the following functions: (1) feature detection, (2) isotopes and adducts/fragments annotation, (3) feature alignment across samples, (4) filtering features using controls, (5) calculating exact mass based on adducts/fragments for compound database search.
-
Please log in and upload files before use.
Data preparation is described in the MSConvert Usage section.
-
Check the parameter settings.
The default
parameterssettings are designed to be compatible with Q-TOF systems from different manufacturers, such as Waters, SCIEX, Thermo, etc. Users may modify these parameters as needed for their particular analytical purposes.Parameter & Description Default Setting Isotope match False Signal intensity threshold for controls 1000 Signal intensity threshold for samples 10000 ppm tolerance 20 Delta MZ 0.01 Min peak width 9 Max peak width 20 Rt Check: delta retention time (in seconds) that is allowed to match two features within a sample 30 Noise level for controls 100 Noise level for samples 1000 Calculate adducts/fragments Ture SNR threshold: Features with signal-to-noise ratios lower than this value are not included in analysis 2 perfwhm: This parameter is used to group two features depending on their retention time. Typically between 0.6 and 1.2. Default is 1. 1 Remove control signals with stringent criteria: If true, rigorous filtering will be performed to ensure features that can be found in control groups are removed from samples of interest. This slows down the computation and may remove some true hits. Ture RT tolerance: Delta retention time (in seconds) that is allowed to match two features between samples. Determined mainly by experimental conditions. 60 Fold change filter: When the signal intensity in the sample of interest exceeds the signal intensity in the controls by a certain fold, such a signal is retained for analysis. If set to 0, signals detected in controls are all removed from samples of interest. 0 Intensity threshold for adducts calculation 5000 Context-based adducts/fragments calculation Ture Polarity Positive -
Upload the corresponding files under the option.
The
Compound Library to Searchoption offers NPA and COCONUT databases. Users can choose either as needed; selecting "None" will search both databases.Data files for control: Choose your single or multiple control data files, support .mzXML format.Data files for sample of interest: Choose your single or multiple data files for samples of interest, support .mzXML format. -
Enter a task name to start your analysis journey.
Click "Tasks" at any time to check your analysis progress.

-
Data output.
The output includes eight files. The .json file records all parameter settings from the user's submitted task, while FilteredList.csv provides the final results.
-
Data analysis. A brief explanation of the key output results in the FilteredList.csv file is provided below.
Columns Description mz, mzmin, mzmax The m/z value of the metabolite and its fluctuation range within the file rt, rtmin, rtmax The retention time (in seconds) of the metabolite and its fluctuation range within the file adducts, exact mass Calculated adducts and exact mass of the metabolite BALF-D2-PBS-1, BALF-D2-PBS-2(An example of the file name) The uploaded file name. Numbers in each column indicate relative abundances calculated from the peak intensities of the corresponding m/z values; “-1“ means the abundance falls below the defined threshold. match The compound database search result for the corresponding metabolite m/z is output as an InChIKey (copyable to PubChem https://pubchem.ncbi.nlm.nih.gov/ for structure lookup); “-1” means no matching m/z found in the specified database.